Makishima, Akio & Nakamura, Eizo (2012) High-resolution MC-ICPMS employing amplifers with a 10 12 ohm resistor for bulk sulfur determination in biological and geological samples, Journal of Analytical Atomic Spectrometry, 27, 891-895, doi:10.1039/c2ja10337k. < 20191223144532-884161 > pub
Table 2 Sulfur concentrations for silicate reference materials and carbonaceous chondrites determined by ID-HR-MC-ICPMS and in references < 20191223151545-280524 > pub
measured unit JB-2 JB-3 powder JA-2 JA-3 powder JP-1 BCR-2 BHVO-1 AGV-1 Murchison Allende-12 Dar al Gani 521 Dar al Gani 194
[S] a µg/g 17.0 (8.0) 5.64 (3.0) 6.61 (2.0) 214.0 (4.0) 29.4 (4.0) 334.0 (1.0) 84.8 (1.0) 15.0 (9.0) 26600.0 (30000.0) 2.08 (6.0) 0.288 (6.0) 2.12 (3.0)
(a) determined by HR-ICPMS on ICPMS Thermo-Fisher Neptune
name physical-form quantity unit global-id
JB-2 pub powder 20130416090250-887738
JB-3 powder pub aliquot 1.56 g 20170620122529-773001
JA-2 pub powder 20160921101920-406882
JA-3 powder pub aliquot 1.9 g 20170620122603-026842
JP-1 pub powder 12.8 g 20190301111946-454924
BCR-2 pub powder 20130416090303-875743
BHVO-1 pub powder 20130416090323-009811
AGV-1 pub powder 20130416090329-701068
Murchison pub powder 0.4521 g 20120710094735-522-706
Allende-12 pub aliquot 0.51212 g 20071216135000.en
Dar al Gani 521 pub aliquot 20071205074652.en
Dar al Gani 194 pub aliquot 125.1178 g 20071205074728.en

The table is created from analysis shown below. The rowname S (Max et al., 2001) filters out analysis. Upper analysis has priority.To list more analysis, add a stone in stone sub-tab.

  • name
    technique
    device
    priority
JB-2 JB-3 powder JA-2 JA-3 powder JP-1 BCR-2 BHVO-1 AGV-1 Murchison Allende-12 Dar al Gani 521 Dar al Gani 194