Lu et al. (2007) Coprecipitation of Ti, Mo, Sn and Sb with fluorides and application to determination of B, Ti, Zr, Nb, Mo, Sn, Sb, Hf and Ta by ICP-MS, Chemical Geology, 236, 13-26, doi:10.1016/j.chemgeo.2006.08.007. < 20100403101828279.admin > pub
Table 5. Analytical results for basalt standard reference materials < 20191024101246-343357 > pub
measured unit JB-1b JB-2 JB-3 powder BHVO-1
[B] a µg/g 8.45 31.2 20.7 (0.9) 2.39
[Zr] a µg/g 126.0 42.9 86.2 (0.7) 165.0
[Nb] a µg/g 34.6 0.459 1.87 17.0
[Mo] a µg/g 30.8 0.96 1.12 (2.6) 0.986
[Sn] a µg/g 1.99 0.718 1.04 (7.8) 1.86
[Sb] a µg/g 0.3 0.224 0.104 (2.7) 0.146
[Hf] a µg/g 3.44 1.45 2.65 (1.3) 4.42
[Ta] a µg/g 2.32 0.0307 0.114 1.1
[TiO2] a % 1.25 1.16 1.37 (2.9) 2.67
(a) determined by ICPMS with isotope dilution and internal standardization on Q-ICPMS Agilent 7500cs
name physical-form quantity unit global-id
JB-1b pub powder 20160921102320-366434
JB-2 pub powder 20130416090250-887738
JB-3 powder pub aliquot 1.56 g 20170620122529-773001
BHVO-1 pub powder 20130416090323-009811

The table is created from analysis shown below. The rowname Zr-Nb-Hf-Ta (Lu et al., 2007) filters out analysis. Upper analysis has priority.To list more analysis, add a stone in stone sub-tab.

  • name
    technique
    device
    priority
JB-1b JB-2 JB-3 powder BHVO-1