Akio Makishima & Eizo Nakamura (1997) Suppression of matrix effects in ICP-MS by high power operationof ICP: Application to precise determination of Rb, Sr, Y, Cs, Ba, REE, Pb, Th and U at ng g(-1) levels in milligram silicate samples, Geostandards Newsletter, 21, 307-319, doi:10.1111/j.1751-908X.1997.tb00678.x. < 20191007145555-553597 > pub
Tables 4. Trace element concentrations in DTS-1, PCC-1 and JP-1 < 20191007152810-466710 > pub
measured unit DTS-1 PCC-1 JP-1
[Rb] a µg/g 0.084 0.083 0.34
[Sr] a µg/g 0.32 0.37 0.57
[Y] a µg/g 0.042 0.079 0.1
[Cs] a µg/g 0.0069 0.0052 0.035
[Ba] a µg/g 0.33 0.89 9.8
[Pb] a µg/g 7.5 7.9 0.09
[Th] a µg/g 0.011 0.012 0.012
[U] a µg/g 0.003 0.0051 0.012
[La] a µg/g 0.023 0.034 0.03
[Ce] a µg/g 0.052 0.061 0.054
[Pr] a µg/g 0.0066 0.0091 0.0071
[Nd] a µg/g 0.025 0.035 0.033
[Sm] a µg/g 0.009 0.0095 0.013
[Eu] a µg/g 0.0019 0.0024 0.0034
[Gd] a µg/g 0.0081 0.013 0.013
[Tb] a µg/g 0.0012 0.0014 0.0026
[Dy] a µg/g 0.0082 0.016 0.018
[Ho] a µg/g 0.0024 0.0034 0.0043
[Er] a µg/g 0.0061 0.016 0.014
[Tm] a µg/g 0.0017 0.0032 0.0027
[Yb] a µg/g 0.011 0.028 0.021
[Lu] a µg/g 0.0029 0.0054 0.0047
(a) determined by Q-ICP-MS_procedures of Makishima and Nakamura (1997, 1999, 2006) on ICPMS Yokogawa PMS2000
name physical-form quantity unit global-id
DTS-1 pub powder 20140606085058-007340
PCC-1 pub powder 20100824093541348.hkitagawa
JP-1 pub powder 12.8 g 20190301111946-454924

The table is created from analysis shown below. The rowname trace (Max et al., 1997) filters out analysis. Upper analysis has priority.To list more analysis, add a stone in stone sub-tab.

  • name
    technique
    device
    priority
DTS-1 PCC-1 JP-1 JB-2 does not refer to
  • B_procedures of Makishima et al. (1997)
    ICPMS Yokogawa PMS2000
    165