Volvic France < 20181024100104-162416 > pub
  • technique: FDC-ID-IS method for water samples
  • device: ICPMS
  • operator: Que
  • modified at 2018-10-24
  • stone: Volvic France
measured value uncertainty unit
[Li] 9.57 ng/g
[Be] 0.543 pg/g
[B] 4.7 ng/g
[Na] 13.3 µg/g
[Mg] 9.26 µg/g
[Al] 0.544 ng/g
[P] 195.0 ng/g
[K] 7.12 µg/g
[Ca] 13.5 µg/g
[Sc] 0.706 pg/g
[Ti] 18.2 pg/g
[V] 6.16 ng/g
[Mn] 26.2 pg/g
[Fe] 44.6 pg/g
[Co] 10.4 pg/g
[Ni] 56.1 pg/g
[Cu] 125.0 pg/g
[Ga] 4.91 pg/g
[Rb] 6.11 ng/g
[Sr] 0.0677 µg/g
[Y] 2.93 pg/g
[Zr] 1.97 pg/g
[Nb] 0.791 pg/g
[Mo] 0.45 ng/g
[Cd] 0.362 pg/g
[In] 0.0341 pg/g
[Sn] 0.529 pg/g
[Sb] 1.29 pg/g
[Cs] 52.1 pg/g
[Ba] 0.372 ng/g
[La] 0.719 pg/g
[Ce] 0.121 pg/g
[Pr] 0.226 pg/g
[Nd] 1.0 pg/g
[Sm] 0.338 pg/g
[Eu] 0.0713 pg/g
[Gd] 0.347 pg/g
[Tb] 0.045 pg/g
[Dy] 0.277 pg/g
[Ho] 0.068 pg/g
[Er] 0.235 pg/g
[Tm] 0.0412 pg/g
[Yb] 0.316 pg/g
[Lu] 0.083 pg/g
[Ta] 0.021 pg/g
[Tl] 0.444 pg/g
[Pb] 0.501 pg/g
[Bi] 0.0288 pg/g
[Th] 0.0451 pg/g
[U] 241.0 pg/g
name global-id