I2117 < 20110603191733-628-266 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I2117
measured value uncertainty unit description
[Li] 5.2 µg/g
[Be] 0.728 µg/g
[B] 0.581 µg/g
[Rb] 1.06 µg/g
[Sr] 268.0 µg/g
[Y] 29.8 µg/g
[Zr] 123.0 µg/g
[Nb] 12.0 µg/g
[Cs] 0.0084 µg/g
[Ba] 67.1 µg/g
[La] 10.6 µg/g
[Ce] 26.7 µg/g
[Pr] 3.78 µg/g
[Nd] 18.1 µg/g
[Sm] 4.76 µg/g
[Eu] 1.76 µg/g
[Gd] 5.1 µg/g
[Tb] 0.867 µg/g
[Dy] 5.15 µg/g
[Ho] 1.07 µg/g
[Er] 2.72 µg/g
[Tm] 0.395 µg/g
[Yb] 2.57 µg/g
[Lu] 0.352 µg/g
[Hf] 3.25 µg/g
[Ta] 0.845 µg/g
[Pb] 0.666 µg/g
[Th] 0.784 µg/g
[U] 0.242 µg/g
name global-id
name spots global-id