I2110 < 20110603191726-359-970 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I2110
measured value uncertainty unit description
[Li] 4.88 µg/g
[Be] 0.688 µg/g
[B] 0.322 µg/g
[Rb] 2.63 µg/g
[Sr] 267.0 µg/g
[Y] 30.5 µg/g
[Zr] 128.0 µg/g
[Nb] 10.2 µg/g
[Cs] 0.0095 µg/g
[Ba] 68.6 µg/g
[La] 9.36 µg/g
[Ce] 24.9 µg/g
[Pr] 3.58 µg/g
[Nd] 17.2 µg/g
[Sm] 4.71 µg/g
[Eu] 1.72 µg/g
[Gd] 5.19 µg/g
[Tb] 0.881 µg/g
[Dy] 5.3 µg/g
[Ho] 1.07 µg/g
[Er] 2.79 µg/g
[Tm] 0.402 µg/g
[Yb] 2.56 µg/g
[Lu] 0.365 µg/g
[Hf] 3.35 µg/g
[Ta] 0.724 µg/g
[Pb] 0.62 µg/g
[Th] 0.706 µg/g
[U] 0.185 µg/g
name global-id
name spots global-id