I1510 < 20110603191659-404-164 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I1510
measured value uncertainty unit description
[Li] 4.11 µg/g
[Be] 1.24 µg/g
[B] 1.29 µg/g
[Rb] 9.16 µg/g
[Sr] 350.0 µg/g
[Y] 44.0 µg/g
[Zr] 212.0 µg/g
[Nb] 21.6 µg/g
[Cs] 0.105 µg/g
[Ba] 168.0 µg/g
[La] 19.9 µg/g
[Ce] 48.2 µg/g
[Pr] 6.55 µg/g
[Nd] 30.6 µg/g
[Sm] 7.53 µg/g
[Eu] 2.66 µg/g
[Gd] 7.99 µg/g
[Tb] 1.32 µg/g
[Dy] 7.67 µg/g
[Ho] 1.54 µg/g
[Er] 3.84 µg/g
[Tm] 0.541 µg/g
[Yb] 3.58 µg/g
[Lu] 0.495 µg/g
[Hf] 5.32 µg/g
[Ta] 1.53 µg/g
[Pb] 1.48 µg/g
[Th] 1.63 µg/g
[U] 0.478 µg/g
name global-id
name spots global-id