I1413 < 20110603191638-358-574 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I1413
measured value uncertainty unit description
[Li] 8.56 µg/g
[Be] 1.01 µg/g
[B] 0.527 µg/g
[Rb] 2.54 µg/g
[Sr] 277.0 µg/g
[Y] 47.9 µg/g
[Zr] 214.0 µg/g
[Nb] 18.9 µg/g
[Cs] 0.0158 µg/g
[Ba] 108.0 µg/g
[La] 17.8 µg/g
[Ce] 43.7 µg/g
[Pr] 6.09 µg/g
[Nd] 29.3 µg/g
[Sm] 7.54 µg/g
[Eu] 2.65 µg/g
[Gd] 8.11 µg/g
[Tb] 1.39 µg/g
[Dy] 8.21 µg/g
[Ho] 1.68 µg/g
[Er] 4.16 µg/g
[Tm] 0.604 µg/g
[Yb] 4.02 µg/g
[Lu] 0.56 µg/g
[Hf] 5.61 µg/g
[Ta] 1.33 µg/g
[Pb] 1.21 µg/g
[Th] 1.61 µg/g
[U] 0.478 µg/g
name global-id
name spots global-id