I1409 < 20110603191635-752-735 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I1409
measured value uncertainty unit
[Li] 4.44 µg/g
[Be] 1.19 µg/g
[B] 1.01 µg/g
[Rb] 5.26 µg/g
[Sr] 364.0 µg/g
[Y] 48.1 µg/g
[Zr] 229.0 µg/g
[Nb] 23.1 µg/g
[Cs] 0.432 µg/g
[Ba] 153.0 µg/g
[La] 19.8 µg/g
[Ce] 49.1 µg/g
[Pr] 6.59 µg/g
[Nd] 31.4 µg/g
[Sm] 8.07 µg/g
[Eu] 2.8 µg/g
[Gd] 8.53 µg/g
[Tb] 1.43 µg/g
[Dy] 8.18 µg/g
[Ho] 1.69 µg/g
[Er] 4.26 µg/g
[Tm] 0.599 µg/g
[Yb] 3.89 µg/g
[Lu] 0.535 µg/g
[Hf] 5.71 µg/g
[Ta] 1.6 µg/g
[Pb] 1.36 µg/g
[Th] 1.9 µg/g
[U] 0.55 µg/g
name global-id
name spots global-id