I1401 < 20110603191626-681-212 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I1401
measured value uncertainty unit
[Li] 9.25 µg/g
[Be] 0.62 µg/g
[B] 2.02 µg/g
[Rb] 4.89 µg/g
[Sr] 328.0 µg/g
[Y] 23.0 µg/g
[Zr] 103.0 µg/g
[Nb] 9.41 µg/g
[Cs] 0.139 µg/g
[Ba] 74.2 µg/g
[La] 8.95 µg/g
[Ce] 23.1 µg/g
[Pr] 3.23 µg/g
[Nd] 15.5 µg/g
[Sm] 4.01 µg/g
[Eu] 1.54 µg/g
[Gd] 4.2 µg/g
[Tb] 0.692 µg/g
[Dy] 4.04 µg/g
[Ho] 0.819 µg/g
[Er] 2.0 µg/g
[Tm] 0.282 µg/g
[Yb] 1.84 µg/g
[Lu] 0.256 µg/g
[Hf] 2.66 µg/g
[Ta] 0.663 µg/g
[Pb] 0.622 µg/g
[Th] 0.706 µg/g
[U] 0.239 µg/g
name global-id
name spots global-id