I1308 < 20110603191618-153-231 > pub
  • technique: ICPMS (0)
  • device: ICPMS Yokogawa PMS2000/Agilent 7500cs
  • operator: hkitagawa
  • description: Methods applied are those described in Makishima et al. (1997, 1999), Makishima and Nakamura (1997, 2006), Yokoyama et al. (1999), Moriguti et al. (2004), and Lu et al. (2007)
  • modified at 2011-06-04
  • stone: I1308
measured value uncertainty unit
[Li] 4.75 µg/g
[Be] 1.0 µg/g
[B] 1.12 µg/g
[Rb] 16.5 µg/g
[Sr] 636.0 µg/g
[Y] 30.3 µg/g
[Zr] 155.0 µg/g
[Nb] 17.0 µg/g
[Cs] 0.0427 µg/g
[Ba] 169.0 µg/g
[La] 15.6 µg/g
[Ce] 37.7 µg/g
[Pr] 5.04 µg/g
[Nd] 23.3 µg/g
[Sm] 5.8 µg/g
[Eu] 2.12 µg/g
[Gd] 6.01 µg/g
[Tb] 0.942 µg/g
[Dy] 5.55 µg/g
[Ho] 1.09 µg/g
[Er] 2.6 µg/g
[Tm] 0.375 µg/g
[Yb] 2.45 µg/g
[Lu] 0.334 µg/g
[Hf] 4.01 µg/g
[Ta] 1.2 µg/g
[Pb] 1.07 µg/g
[Th] 1.26 µg/g
[U] 0.416 µg/g
name global-id
name spots global-id